Advantech EKI-1242OUMS

Modbus TCP/RTU to OPC UA Fieldbus Gateway

Advantech EKI-1242OUMS
7687_32558.png
7687_32559.jpg
7687_32560.jpg
  • EigenschaftenEigenschaften
  • BeschreibungBeschreibung
  • Weitere InformationenWeitere Informationen
  • PDFPDF
  • Supports dual power input for power redundancy
  • Seamless integrate Modbus RTU/TCP and OPC UA communication
  • Modbus Master mode supports 64 connections
  • Mounts on DIN-rail and Wall mount
  • Designed for protocol extensibility and adaption
  • Built-in real time diagnostic to increase highly efficiency of device management
  • 'I' models support a wide operating temperature
The EKI-1242OUMS provides seamless communication between fieldbus and industrial automation developed and supports different protocol devices integrating new and existing Modbus RTU/TCP devices with OPC-UA networks
ProdGrafik

Specifications

    Ethernet Communication

      Protocols
      OPC UA, Modbus TCP

      Number of Ports
      4

      Speed
      10/100 Mbps, Auto MDI/MDIX

      Connector
      8-pin RJ45

      Protection
      Built-in 1.5 KV magnetic isolation



    Serial Communications

      Port Type
      RS-232/422/485, software selectable

      No. of Ports
      2

      Protocol Modbus
      RTU

      Port Connector
      DB9 male

      Data Bits
      5, 6, 7, 8

      Stop Bits
      1, 1.5, 2 Parity None, Odd, Even, Space, Mark

      Flow Control
      XON/XOFF, RTS/CTS

      Baud Rate
      50 bps ~ 921.6 kbps

      Serial Signals
      RS-232: TxD, RxD, CTS, RTS, DCD, RI, GND
      RS-422: TxD+, TxD-, RxD+, RxD-, GND
      RS-485: Data+, Data-, GND



    Software

      Modbus RTU/TCP
      Mode Master
      Functions Support 1, 2, 3, 4, 5, 6, 15, 16, 23
      Max. Number of Connections 64 connections

      OPC UA
      Type Server
      Max. Number of Connections 128 connections



    General

      LED Indicators
      System: Power, System Status, Protocol status
      LAN: Speed, Link/Active, Error

      Reboot Trigger
      Built-in WDT (watchdog timer)

      MicroSD Card
      Configuration backup and restore



    Mechanics

      Dimensions (W x H x D)
      42 x 140 x 95 mm (1.66" x 5.52" x 3.75")

      Enclosure
      Metal with solid mounting hardware

      Mounting
      DIN-rail, Wall

      Weight
      0.497 Kg



    Power Requirements

      Power Input
      12 ~ 48 VDC, redundant dual inputs

      Power Connector
      Terminal block

      Power Consumption
      5.2 W



    Environment

      Operating Temperature
      -10 ~ 60 °C (14 ~ 140 °F)
      ' I' models: -40 ~ 75 °C (-40 ~ 167 °F)

      Storage Temperature
      -40 ~ 85 °C (-40 ~ 185 °F)

      Operating Humidity
      10 ~ 95% RH



    Regulatory Approvals

      EMC
      CE, FCC Part 15 Subpart B (Class A)




ORDERING INFORMATION

Available Modules
EKI-1242OUMS Modbus TCP/RTU to OPC UA Fieldbus Gateway
EKI-1242IOUMS Modbus TCP/RTU to OPC UA Fieldbus Gateway with wide operating temperature



Kunden, die diesen Artikel gesehen haben, sahen auch
Alle Cookies akzeptieren Ablehnen Konfigurieren

Diese Website verwendet Cookies, um eine bestmögliche Erfahrung bieten zu können. Mehr erfahren.