Advantech BB-422TTL
RS-422 to TTL Converter
- Convert 2 channels in each direction from TTL (“Transistor Transistor Logic)” to RS-422
- 5V TTL
- Baud rates up to 115.2 kbps
- Open pads to change pin configuration
Model 422TTL converts RS-422 or EIA-530 signals to 5V TTL at data rates up to 115.2 kbps. Two channels are used to convert RS-422 to TTL and two channels are used to convert TTL to RS-422.
A DB25 male connector is used on the TTL side and a DB25 female connector is used on the RS-422/EIA-530 side. The converter supports RD, TD, RTS, and CTS. Pin 7 is signal ground for both connectors.
The converter supports baud rates up to 115.2 kbps. Open pads are provided for each line. If desired, you can change the pin connectors for any of the 4 channels. When converting a second RS-422 channel, use the corresponding RTS A and RTS B pins (refer to the Quick Start Guide).
The converter inverts the TTL signal. Refer to the specifications table to determine polarity. An external +12 VDC power supply is required (not included).
A DB25 male connector is used on the TTL side and a DB25 female connector is used on the RS-422/EIA-530 side. The converter supports RD, TD, RTS, and CTS. Pin 7 is signal ground for both connectors.
The converter supports baud rates up to 115.2 kbps. Open pads are provided for each line. If desired, you can change the pin connectors for any of the 4 channels. When converting a second RS-422 channel, use the corresponding RTS A and RTS B pins (refer to the Quick Start Guide).
The converter inverts the TTL signal. Refer to the specifications table to determine polarity. An external +12 VDC power supply is required (not included).
SPECIFICATIONS
SERIAL TECHNOLOGY | |
Data Rate | 115.2 kbps maximum |
RS-422 | |
Connector | DB25 female |
Signals (EIA-530 pinout) | TDA(-), TDB(+), RDA(-), RDB(+), RTS A(-), RTS B(+), CTS A(-), CTS B(+) |
TTL | |
Connector | DB25 male |
Signals | TD, RD, RTS, CTS |
VDC Level | 5 V |
POLARITY (VOLTS) | |
TTL Input | V(A) - V(B) |
High | Negative |
Low | Positive |
TTL Output | RS-422 / EIA-530 Input |
High | Negative |
Low | Positive |
POWER | |
Power Source | External (2.5 mm positive tip) |
Input Voltage | 12 VDC (<100 mA) |
MECHANICAL | |
Dimensions | 5.4 x 5.1 x 1.6 cm (2.1 x 2.02 x 0.62 in |
MEANTIME BEFORE FAILURE (MTBF) | |
MTBF | 1539882 hours |
MTBF Calc. Method | MIL 217F Parts Count Reliability Prediction |
ENVIRONMENTAL | |
Operating Temperature | 0 to +70 °C (+32 to +158 °F) |
Storage Temperature | -40 to +85 °C (-40 to +185 °F) |
Operating Humidity | 0 to 95% non-condensing |
APPROVALS / CERTIFICATIONS | |
FCC Part 15, CISPR, EN 55022 +AC Class A Emissions | |
CE | |
EN 61000-6-1 | Generic Standards for Residential, Commercial, Light-Industrial Environments |
EN 61000-4-2 | Electro-Static Discharge (ESD) |
EN 61000-4-3 +A1 +A2 +IS1 | Radiated Field Immunity (RFI) |
EN 61000-4-4 | Electrical Fast Transients-Burst Immunity (EFT) |
EN 61000-4-6 | Conducted Immunity |
Kunden, die diesen Artikel gesehen haben, sahen auch