Advantech BB-232SPHI4

SPHINX in Europa
CH
  • AT
  • BE
  • DK
  • FR
  • DE
  • IE
  • IT
  • NL
  • ES
  • SE
  • CH
  • UK
Produktgruppen > Protection Modules > Advantech BB-232SPHI4

Advantech BB-232SPHI4

RS-232 Optical Isolator - 4kV Isolation, Port Power

Advantech BB-232SPHI4
5539_17043.png
5539_17044.jpg
  • EigenschaftenEigenschaften
  • BeschreibungBeschreibung
  • Weitere InformationenWeitere Informationen
  • PDFPDF
  • 4,000V, 2-way optical isolation
  • DB25 male and DB25 female connectors
  • Port-powered (or optional external 12VDC power supply)
Model 232SPHI4 isolates and protects RS-232 equipment from lightning surges, accidental high voltage shorts and ground loops. The isolator supports RS-232 data signals up to 115.2 kbps as well as RTS and CTS handshake lines. Model 232SPHI4 provides 4000 Volts isolation between sides — twice the rating of most isolators. DTE device connections are made through a DB-25 female. DCE device connections are made through a DB-25 male.

The two sides of the isolator are powered independently to maintain isolation. Both sides can draw power from the RS-232 data and handshake lines, eliminating external powering requirements in nearly all systems.

If the isolator is to be used with low power ports or when no handshake lines are available, external power can be supplied to either side or both. This versatile powering configuration minimizes the number of supplies required by the overall system.
ProdGrafik

SPECIFICATIONS

SERIAL TECHNOLOGY
Data Rate 115.2 kbps maximum
RS-232
Connector DB25 female (DTE)
Connector DB25 male (DCE)
Signals TD, RD, RTS, CTS
Transmission Mode Asynchronous, half or full duplex, point-to-point
POWER
Source Port-powered from RS-232 data and handshake lines
Optional External Source 12 VDC
External Connections 2.5mm power jacks (tip positive) or
DB25 connectors pins 11 (+) and 12 (-)
ISOLATION
Volts/Duration 4,000 Volts RMS isolation for 1 minute
(may be limited by external supply)
MECHANICAL
Dimensions 10.4 x 5.8 x 2.4 cm (4.1 x 2.3 x 0.95 in)
Minimum Air Clearance
between DTE & DCE Sides:
5 mm (0.197 in)
Minimum Creepage Distance
between DTE & DCE Sides:
8 mm (0.315 in)
ENVIRONMENTAL
Operating Temperature 0 to +70 °C
Storage Temperature -55 to 125 °C
Operating Humidity 10 to 90% Non-Condensing
MTBF 351896
MTBF Calc. Method Parts Count Reliability Prediction
APPROVALS / CERTIFICATIONS - 232SPHI4
FCC Part 15, CISPR, EN55032
CE
EN 61000-6-1: 2007 Generic Standards for Residential, Commercial and LightIndustrial Environments
EN 61000-4-2: 2009 Electro-Static Discharge (ESD)
EN 61000-4-3: 2006 +A1 +A2 +IS1 Radiated Field Immunity (RFI)
EN 61000-4-4: 2012 Electrical Fast Transients-Burst Immunity (EFT)