MOXA IEX-402-VDSL2 Series
Product is End of Life : 2022-01-28
Managed VDSL2 Ethernet extender
- Automatic CO/CPE negotiation reduces configuration time
- Standard VDSL2 data rate up to 100 Mbps, with up to 3 km transmission distance (performance varies with line conditions)
- Supports Link Fault Pass-Through(LFP)
- Supports SNMP v1/v2c/v3 for different levels of network management
- Interoperable with Turbo Ring/Turbo Chain network redundancy
- Support Modbus/TCP protocol for device management and monitoring
- Compatible with EtherNet/IP and PROFINET protocols for transparent transmission
- Easy network management through web browser, Telnet/Serial console, Windows utility, MXview, and ABC-01
- IPv6 Ready
Der IEX-402-VDSL2 ist ein industrieller Managed-Ethernet-Extender für die Erweiterung von LAN-Segmenten auf bis zu 3 km Länge über Twisted-Pair-Kupferleitungen bei Datenraten von bis zu 100 Mbps unter Anwendung des VDSL2-Standards.
Der Ethernet-Extender ist mit einem 10/100BaseT(X)- und einem DSL-Port ausgestattet. Es ist die perfekte Lösung, wenn es gilt, Kupferkabelnetze über die herkömmlichen Ethernet-Begrenzungen hinaus unter Verwendung bestehender Telefonkabel zu erweitern und dabei die Kosten für die Verlegung neuer Netzwerkkabel zu senken.
Der IEX-402-VDSL2 ist für den Einsatz unter rauen Betriebsumgebungen ausgelegt. Er kann auf Hutschienen montiert werden, verfügt über einen erweiterten Betriebstemperaturbereich (-40 bis 75°C) und besitzt zwei Stromversorgungseingänge. Damit eignet er sich ideal für den Einsatz in Industrieanwendungen.
Zur Vereinfachung der Konfiguration wird beim IEX-402-VDSL2 automatische CO/CPE-Negotiation angewandt (Standardeinstellung bei Auslieferung). Hierbei ist das Gerät so vorkonfiguriert, dass es automatisch einem Gerät aller IEX-Gerätepaare den Status als Teilnehmer-Endgerät (CPE-Status) zuweist. Durch die LFP-Funktion (Link Fault Pass-through) und die Interoperabilität mit der Netzwerk-Redundanz werden die Zuverlässigkeit und Anbindung von Kommunikationsnetzen weiter verbessert. Fortschrittliche Management- und Überwachungsfunktionen mit NMS einschließlich eines virtuellen Bedienfeldes bieten dem Anwender komfortable Möglichkeiten zur Fehlerbehebung.
Der IEX-402-VDSL2 ist für den Einsatz unter rauen Betriebsumgebungen ausgelegt. Er kann auf Hutschienen montiert werden, verfügt über einen erweiterten Betriebstemperaturbereich (-40 bis 75°C) und besitzt zwei Stromversorgungseingänge. Damit eignet er sich ideal für den Einsatz in Industrieanwendungen.
Zur Vereinfachung der Konfiguration wird beim IEX-402-VDSL2 automatische CO/CPE-Negotiation angewandt (Standardeinstellung bei Auslieferung). Hierbei ist das Gerät so vorkonfiguriert, dass es automatisch einem Gerät aller IEX-Gerätepaare den Status als Teilnehmer-Endgerät (CPE-Status) zuweist. Durch die LFP-Funktion (Link Fault Pass-through) und die Interoperabilität mit der Netzwerk-Redundanz werden die Zuverlässigkeit und Anbindung von Kommunikationsnetzen weiter verbessert. Fortschrittliche Management- und Überwachungsfunktionen mit NMS einschließlich eines virtuellen Bedienfeldes bieten dem Anwender komfortable Möglichkeiten zur Fehlerbehebung.
Technology
Standards
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X)
IEEE 802.3x for Flow Control
IEEE 802.1p for Class of Service
ITU G.993.2 for very high speed digital subscriber line transceivers 2
Protocols
SNMPv1/v2c/v3, DHCP Client, TFTP, SNTP, HTTP, Telnet, Syslog, LLDP, Modbus/TCP
MIB
MIB-II
Flow Control
IEEE 802.3x flow control, back pressure flow control
Switch Properties
MAC Table Size
1K
Packet Buffer Size
512K
Interface
DSL Port
DSL Port: RJ-11(RJ-45 connector) or detachable 2-contact terminal block
RJ45 Ports
10/100BaseT(X) auto negotiation speed, Full/Half duplex mode, and auto MDI/MDI-X connection
DIP Switches
CO/CPE, SNR/SPEED, STD/INP
LED Indicators
PWR1, PWR2, FAULT, STATE, LINK/ACT, CO/CPE, 10/100 (TP port)
Console Port
RS-232 (RJ45 connector)
Button
Reset button
Power Requirements
Input Voltage
12/24/48 VDC (9.6 to 60 VDC), redundant dual inputs
Input Current
0.33A @ 24V
Overload Current Protection
Present
Connection
2 removable 2-contact terminal block
Reverse Polarity Protection
Present
Physical Characteristics
Housing
Metal, IP30 protection
Dimensions
35 x 130 x 105 mm (1.37 x 5.12 x 4.13 in)
Weight
275 g
Installation
DIN-rail mounting, wall mounting (with optional kit)
Altitude
Up to 2000 m
Note Contact us for products guaranteed to function at higher altitudes.
Environmental Limits
Operating Temperature
Standard Models: -10 to 60°C (14 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5 to 95% (non-condensing)
Standards and Certifications
Safety
UL 508
Hazardous Location
UL/cUL Class 1 Division 2 Groups A/B/C/D, ATEX Zone 2 Ex nA IIC T4 Gc
EMI
FCC Part 15 Subpart B Class A, EN 55022 Class A
EMS
EN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 3,
EN 61000-4-4 (EFT) Level 3, EN 61000-4-5 (Surge) Level 3,
EN 61000-4-6 (CS) Level 3, EN 61000-4-8
Rail Traffic
EN 50121-4
Shock
IEC 60068-2-27
Freefall
IEC 60068-2-32
Vibration
IEC 60068-2-6
MTBF (mean time between failures)
Time
1,490,000 hrs
Database
Telcordia (Bellcore), GB
Ordering Information
Standards
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X)
IEEE 802.3x for Flow Control
IEEE 802.1p for Class of Service
ITU G.993.2 for very high speed digital subscriber line transceivers 2
Protocols
SNMPv1/v2c/v3, DHCP Client, TFTP, SNTP, HTTP, Telnet, Syslog, LLDP, Modbus/TCP
MIB
MIB-II
Flow Control
IEEE 802.3x flow control, back pressure flow control
Switch Properties
MAC Table Size
1K
Packet Buffer Size
512K
Interface
DSL Port
DSL Port: RJ-11(RJ-45 connector) or detachable 2-contact terminal block
RJ45 Ports
10/100BaseT(X) auto negotiation speed, Full/Half duplex mode, and auto MDI/MDI-X connection
DIP Switches
CO/CPE, SNR/SPEED, STD/INP
LED Indicators
PWR1, PWR2, FAULT, STATE, LINK/ACT, CO/CPE, 10/100 (TP port)
Console Port
RS-232 (RJ45 connector)
Button
Reset button
Power Requirements
Input Voltage
12/24/48 VDC (9.6 to 60 VDC), redundant dual inputs
Input Current
0.33A @ 24V
Overload Current Protection
Present
Connection
2 removable 2-contact terminal block
Reverse Polarity Protection
Present
Physical Characteristics
Housing
Metal, IP30 protection
Dimensions
35 x 130 x 105 mm (1.37 x 5.12 x 4.13 in)
Weight
275 g
Installation
DIN-rail mounting, wall mounting (with optional kit)
Altitude
Up to 2000 m
Note Contact us for products guaranteed to function at higher altitudes.
Environmental Limits
Operating Temperature
Standard Models: -10 to 60°C (14 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5 to 95% (non-condensing)
Standards and Certifications
Safety
UL 508
Hazardous Location
UL/cUL Class 1 Division 2 Groups A/B/C/D, ATEX Zone 2 Ex nA IIC T4 Gc
EMI
FCC Part 15 Subpart B Class A, EN 55022 Class A
EMS
EN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 3,
EN 61000-4-4 (EFT) Level 3, EN 61000-4-5 (Surge) Level 3,
EN 61000-4-6 (CS) Level 3, EN 61000-4-8
Rail Traffic
EN 50121-4
Shock
IEC 60068-2-27
Freefall
IEC 60068-2-32
Vibration
IEC 60068-2-6
MTBF (mean time between failures)
Time
1,490,000 hrs
Database
Telcordia (Bellcore), GB
Ordering Information
Available Modules | |
IEX-402-VDSL2 | Managed VDSL2 Ethernet extender with 1 10/100BaseT(x) port and 1 DSL port, -10 to 60 °C operating temperature |
IEX-402-VDSL2-T | Managed VDSL2 Ethernet extender with 1 10/100BaseT(x) port and 1 DSL port, -40 to 75 °C operating temperature |